TM 1-1520-238-23
9-168
9.50.
GROUND SERVICE UTILITY RECEPTACLE REMOVAL/INSTALLATION continued
c. Remove receptacle J16 (1) from mounting
plate (2).
(1) Remove four nuts (3) and washers (4) from
screws (5).
(2) Remove four screws (5).
(3) Push receptacle (1) up and inboard to re-
move from plate (2).
d. Remove backshell (6) from receptacle (1).
(1) Remove two screws (7) and retaining clamps
(8) from backshell (6).
(2) Loosen backshell (6).
(3) Slide backshell (6) over wires (9).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
e. Desolder wires (9) from receptacle (1).
(1) Identify wires (9).
(2) Desolder wires (9) (TM 55-1500-323-24).
Use soldering iron.
GO TO NEXT PAGE
5
1
4
3
2
M04-1305-2
M04-1305-5
9
1
6
8
7
7
8