TM 1-1520-238-23
9-303
9.80.
PILOT OR CPG INSTRUMENT GLARESHIELD LAMP REPLACEMENT
9.80.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.80.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1520-238-T
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
NOTE
This task is typical for all lamps in the pilot
and CPG glareshield lights.
9.80.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. On pilot center circuit breaker panel, open LT
UTIL SEC circuit breaker.
c. Enter CPG station (para 1.56). Observe all
safety precautions.
d. On CPG circuit breaker panel No. 1, open EM-
ERG BATT UTIL SEC LT circuit breaker.
GO TO NEXT PAGE
PILOT STATION
CPG STATION
M04-1264-1