TM 1-1520-238-23
9-308
9.82.
CPG INTR LT PANEL CONTROL KNOB REMOVAL/INSTALLATION continued
9.82.4. Cleaning
a. Clean removed and attaching parts (para
1.47).
9.82.5. Inspection
a. Check removed and attaching parts for dam-
age (para 9.61).
b. Check wires and terminals for wear, cracks,
and cuts (para 9.61).
c. Check removed and attaching parts for corro-
sion (para 1.49).
d. Check knobs for damaged threads, cracks, or
wear (para 9.61).
9.82.6. Installation
a. Install knob (1) on panel (2).
(1) Position knob (1) on shaft (4).
(2) Set knob pointer (5) to OFF.
(3) Tighten two setscrews (3). Use socket head
key set.
b. Inspect (QA).
c. Perform CPG edge-lights maintenance opera-
tional check (TM 1-1520-238-T).
END OF TASK
2
5
3
1
4
VIEW
ROTATED
M04-1257-3