TM 1-1520-238-23
9-327
9.89.
CPG INTR LT PANEL RELAY K1 AND SOCKET XK1 REPLACEMENT (AVIM) continued
9.89.6. Installation
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
a. Install new socket (7) on card A1 (1), if re-
moved.
(1) Install socket (7) on card (1).
(2) Solder identified wires (13) on terminals (14).
Use soldering iron and solder (item 189,
App F) (TM 55-1500-323-24).
b. Install new relay (6) on socket (7).
(1) Install relay (6) on socket (7) so that tab on
relay alines with tab on socket.
(2) Install screw (8) through spacer (9), ground-
ing strap (10), card (1), washer (12), and nut
(11).
c. Install card (1) on three tube assemblies (2).
(1) Position card (1) on tube assemblies (2).
(2) Install three screws (3) through lockwashers
(4), washers (5), card (1), and into tube as-
semblies (2).
d. Inspect (QA).
END OF TASK
M04-5082-5
14
1
13
7
8
9
10
6
11
12
1
M04-5082-6
7
2
1
5
4
3
4
3
M04-5082-7
2
5