TM 1-1520-238-23
9-326
9.89.
CPG INTR LT PANEL RELAY K1 AND SOCKET XK1 REPLACEMENT (AVIM) continued
b. Remove relay K1 (6) from socket XK1 (7).
(1) Remove screw (8), spacer (9), grounding
strap (10), nut (11), and washer (12).
(2) Remove and discard relay (6).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
c. Remove socket (7) from card A1 (1), if neces-
sary.
(1) Identify and desolder wires (13) from termi-
nals
(14).
Use
soldering
iron
(TM 55-1500-323-24).
(2) Remove and discard socket (7).
9.89.4. Cleaning
a. Clean removed and attaching parts (para
1.47).
9.89.5. Inspection
a. Check removed and attaching parts for dam-
age (para 9.61).
b. Check wires and terminals for wear, cracks,
and cuts (para 9.61).
c. Check removed and attaching parts for corro-
sion (para 1.49).
GO TO NEXT PAGE
8
9
10
6
11
12
1
M04-5082-3
7
M04-5082-4
14
1
13
7