TM 1-1520-238-23
Change 3 9-499
9.133.
STABILATOR RELAY BOX REMOVAL/INSTALLATION
9.133.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.133.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Light duty laboratory apron (item 27, App H)
Chemical protective gloves (item 154, App H)
Ohmmeter (item 218, App H)
Adjustable air filtering respirator (item 262, App H)
Materials/Parts:
Brush (item 34, App F)
Cloth (item 52, App F)
Methyl ethyl ketone (item 124, App F)
Sealing compound (item 175, App F)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1520-238-T
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
2.2
Access doors T250L, T250R, T290L,
T290R, and L325 opened
9.133.3. Removal
a. Remove stabilator relay box (1).
(1) Detach connector P1077 (2) from relay box
(1).
(2) Remove four screws (3) and washers (4).
(3) Remove relay box (1) from airframe (5).
GO TO NEXT PAGE
M04-3604-1
1
2
4
3
M04-3604-2
5