TM 1-1520-238-23
9-528
9.137.
MASS TERMINATION CONNECTOR (MTC) KEYING continued
CAUTION
To prevent damage to keying pins, only
smooth gripping needle nose pliers will
be used to position keying pins in MTC.
c. Install two keying pins (2) in MTC (1).
(1) Place keying pin (2) in grip of needle nose
pliers (3).
(2) Apply adhesive to slotted end (4) of keying
pin (2).Use adhesive (item 13, App F).
(3) Insert slotted end (4) of keying pin (2) in
square recess hole (5) on MTC (1). Ensure
correct position is maintained in accordance
with Table 9-1.
d. Inspect (QA).
e. Complete repair task for applicable MTC (1)
(para 9.135, 9.136, and 9.138).
END OF TASK
H
M04-3527-2
FACE
PLUG
CODE
KEY
FACE
RECEPTACLE
KEYING CODES
TABLE 9)1
(DARK AREAS SHOW KEY POSITIONS)
S
R
P
N
M
L
K
J
KEY POSITION
G
F
B
C
D
E
A
M04-3527-3
5
1
3
4
2