TM 1-1520-238-23
9-532
9.138.
COAXIAL MASS TERMINATION CONNECTOR (MTC) REPAIR continued
b. If end of cable (8) is unserviceable, or if instal-
ling new cable, strip cable (8) to size illus-
trated.
(1) Strip outer jacket (12).
(2) Strip shield braid (13) from front of cable (8).
(3) Strip primary insulator (14).
(4) Ensure conductor (15) is straight and twisted
to original shape.
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
c. Pre-tin conductor (15). Use soldering iron and
solder (item 189, App F) (TM 55-1500-323-24).
d. Ensure shield braid (13) is trimmed evenly
and no loose strands are exposed.
e. Smooth braid ends (16) against primary in-
sulation (14).
f. Insert cable (8) into contact (6).
(1) Gently slide contact (6) on cable (8).
(2) Rotate contact (6) slightly to prevent braid
(13) from catching.
GO TO NEXT PAGE
14
12
13
15
M04-3067-17
LARGE SIZE COAX
SMALL SIZE COAX
0.185± 0.015 IN
0.185± 0.015 IN
0.090± 0.015 IN
0.185± 0.015 IN
0.160± 0.015 IN
0.035± 0.010 IN
M04-3067-7
14
15
13
16
M04-3067-8
6
13
8