10.19.
FORWARD FUEL CELL FUEL/DEFUEL CHECK VALVE REMOVAL/INSTALLATION continued
b. Install chain assembly (3).
(1) Spread and insert spiral ring (4) through
chain end (5).
(2) Turn ring (4) until fully in chain end (5).
c. Install cap (1) in port (2).
(1) Push cap (1) in port (2).
(2) Turn cap (1) to close position.
d. Inspect (QA).
e. Install forward fuel cell aft cover and access
panel (para 10.8).
END OF TASK