TM 1-1520-238-23
Change 2
10-199
10.39.
AFT FUEL CELL FUEL QUANTITY TRANSMITTER REMOVAL/INSTALLATION continued
e. Remove two bolts (20) and washers (21) from
fuel cell mounting flange (22).
f. Remove transmitter (3) from pressure relief
valve (23).
(1) Hold two upper mounting bolts (24). Remove
two nuts (25) and washers (26).
(2) Remove two bolts (24) and washers (27) from
mounting bracket (28).
10.39.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
10.39.5. Inspection
a. Check removed and attaching parts for cracks
and corrosion (para 10.1).
b. Check fuel quantity transmitter wire harness
for cuts, nicks, and fuel seepage. None al-
lowed.
10.39.6. Adjustment
a. Adjust sensor (17) to 7.00 INCHES.
(1) Loosen two clamps (29).
(2) Measure from upper surface of flange (30) to
lower surface of sensor (17).
(3) Move sensor (17) to 7.00 INCHES from top of
flange (30).
(4) Tighten two clamps (29).
GO TO NEXT PAGE
22
M04-368-5
20
21
M04-368-6
25
26
3
28
24
27
23
7.00 IN
M04-368-13A
29
17
30