TM 1-1520-238-23
10-201
10.39.
AFT FUEL CELL FUEL QUANTITY TRANSMITTER REMOVAL/INSTALLATION continued
c. Attach lead (15) and lead GND (18) to sensor
(17).
(1) Install screw (19) through yellow lead GND
(18) into terminal (33).
(2) Install screw (16) through orange lead (15)
into terminal (34).
d. Attach lead (10) to terminal (12).
(1) Install screw (11) through red lead (10) into
terminal (12).
(2) Place red lead (10) in retainer (14).
(3) Tighten screw (13).
e. Attach lead (1) and lead (2) to transmitter (3).
(1) Install screw (6) through white lead (1) in
transmitter (3).
(2) Position clamp (5) over white lead (1).
(3) Install screw (4) through black lead (2) and
clamp (5) into transmitter (3).
(4) Place white/black lead (8) in retainer (9).
Tighten screw (7).
f. Inspect (QA).
g. Install aft fuel cell aft cover and access panel
(para 10.32).
h. Perform fuel quantity indication/fuel transfer
maintenance
operational
check
(TM 1-1520-238-T).
END OF TASK
M04-368-11
19
16
18
15
17
33
34
4
11
10
14
7
9
5
3
3
M04-368-12
RED
WHITE
12
13
2
6
1
8
BLACK