TM 1-1520-238-23
10-319
10.69.
REFUELING PANEL REMOVAL/INSTALLATION continued
c. Remove refueling panel (1) from mount (2).
(1) Remove eight screws (3) and washers (4).
(2) Detach connector P260 (5) from receptacle
(A57)J1 (6).
(3) Remove panel (1).
10.69.4. Cleaning
a. Clean removed and attaching parts and sur-
faces (para 1.47).
10.69.5. Inspection
a. Check connector for damaged threads, dam-
aged connections, and damaged wire (para
10.1).
10.69.6. Installation
a. Install panel (1) on mount (2).
(1) Attach connector P260 (5) to receptacle
(A57)J1 (6).
(2) Aline panel (1) on mount (2).
(3) Install eight washers (4) and screws (3).
b. Inspect (QA).
c. Perform pressure refueling/defueling mainte-
nance operational check (TM 1-1520-238-T).
d. Secure access door R160 (para 2.2).
END OF TASK
1
M04-292-2
3
2
4
M04-292-3
1
5
6
M04-292-4
1
5
2
6
M04-292-5
FUEL
QTY
E
F
E
F
3
3
1
1
1
1
2
2
4
4
4
4
FUEL QTY
IND ON
OFF
.
AFT CLOSED FWD CLOSED
CLOSE
CLOSE
CLOSE
OPEN
VALVE
REFUEL
LVL CONT VALVES
OPEN
OPEN
OPEN
AFT TNK
FWD TNK
3
4
1