REFUELING PANEL SWITCH REPLACEMENT
10.71.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
10.71.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 55-1500-323-24
NOTE
This task is typical for replacement of
IND, LVL CONT VALVES and RE-
FUEL VALVE switches.
Wire installation shown is typical for all
switches. The number of wires at-
tached to each switch varies.
10.71.3. Removal
a. Remove switch (1) from refueling panel (2).
(1) Identify two wires (3).
(2) Remove two screws (4), lockwashers (5), and
terminal lugs (6) from switch (1).