TM 1-1520-238-23
Change 5
10-321
10.70.
REFUELING INDICATOR REMOVAL/INSTALLATION continued
10.70.6. Installation
a. Install indicator (1) on panel (2).
(1) Position indicator (1) on panel (2).
(2) Install four screws (7), washers (6), and nuts
(5).
(3) Attach connector (A57)P1 (3) to receptacle
(A57)M1J1 (4).
b. Inspect (QA).
END OF TASK
M04-157-2
7
2
1
6
5
4
3