TM 1-1520-238-23
Change 2
10-573
10.135.
FUEL QUANTITY INDICATOR TEST (TF 579) SET INSTALLATION/REMOVAL continued
(16) Detach cable (19) from receptacle (17).
(17) Detach wire (20) from receptacle (18).
(18) Attach adapter IND TEST cable (25) to recep-
tacle (17).
(19) Attach IND TEST wire (26) to receptacle (18).
(20) Repeat steps b.(4) thru b.(10).
(21) Record reading from CAPACITANCE INDI-
CATOR (11). This is TANK 1 and TANK 2 IND
TEST lead capacitance.
(22) Inspect (QA).
(23) Detach cable (25) from receptacle (17).
(24) Detach wire (26) from receptacle (18).
(25) Remove protective caps from TEST IND
COAX receptacle (27) and TEST IND UNSH
receptacle (28).
(26) Attach cable (25) to receptacle (27).
(27) Attach wire (26) to receptacle (28).
(28) Attach cable (19) to receptacle (17).
(29) Attach wire (20) to TANK receptacle (18).
c. On pilot center circuit breaker panel, open
ENG INST circuit breaker.
d. On CPG circuit breaker panel No. 1, open ENG
INST circuit breaker.
GO TO NEXT PAGE
25
26
M04-3075-36
27
28
17
18
19
20
11