TM 1-1520-238-23
10-578
10.136.
FUEL SIGNAL CONDITIONER ADJUSTMENT continued
b. ZERO ADJUSTMENT: Rotate either poten-
tiometer TK1-E or TK2-E counterclockwise to
decrease or clockwise to increase indication.
c. Inspect (QA).
d. FULL ADJUSTMENT: Rotate either potentiom-
eter TK1-F or TK2-F counterclockwise to de-
crease or clockwise to increase indication.
e. Inspect (QA).
f. Torque-stripe potentiometers adjusted in
steps b. and d.
g. Install cover (1) on conditioner (2).
(1) Position cover (1) on conditioner (2).
(2) Install six screws (3).
h. Complete fuel quantity indication/transfer
maintenance
operational
check
(TM 1-1520-238-T).
i. Remove fuel quantity indicator test set (para
10.135).
j. Secure access doors R190, R295, R345;
install panels L40, and B60R (para 2.2).
END OF TASK
SIMPLIFIED
TK1
E
F
F
E
TK2
2
M04-3284-3
1
3
2
M04-3284-4