TM 1-1520-238-23
Change 2
11-156.1
11.29.
COLLECTIVE STICK STORES JETTISON SWITCH REPLACEMENT continued
f. Install indicator panel (5) on grip (6).
(1) Install panel (5) on grip (6).
(2) Install three screws (7).
g. Install knobs (1) and (2) on collective grip (6).
(1) Install knobs (1) and (2) on grip (6).
(2) Tighten setscrews (3) and (4).
h. Inspect (QA).
i. Install collective stick grip assembly (para
11.24).
j. Perform external stores jettison maintenance
operational check (TM 1-1520-238-T).
END OF TASK
1
5
6
7
M04-3514-5A
4
2
3