TM 1-1520-238-23
11-152
11.28.
COLLECTIVE STICK SEARCHLIGHT DIRECTIONAL SWITCH REPLACEMENT continued
11.28.5. Inspection
a. Check for cracked and broken wires. None al-
lowed.
b. Check removed and attaching parts for
cracks. None allowed.
c. Check removed and attaching parts for dam-
age (para 11.5).
d. Check removed and attaching parts for corro-
sion (para 1.49).
11.28.6. Installation
a. Install new switch (10) on plate (8).
(1) Install switch (10) on plate (8).
(2) Tighten setscrew (12).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
b. Solder wires (11) to switch (10).
(1) Solder identified wires (11) to switch (10).
Use soldering iron and solder (item 189,
App F) (TM 55-1500-323-24).
c. Apply a thin coat of adhesive over switch (10)
terminals and bare wires. Use adhesive
(item 14, App F).
GO TO NEXT PAGE
M04-3513-4
10
8
10
11
12
12
VIEW ROTATED
M04-3513-5
9
8
10
6
11