TM 1-1520-238-23
11-178
11.34.
COLLECTIVE STICK SWITCH AND BRACKET ASSEMBLY REMOVAL/INSTALLATION continued
WARNING
To prevent injury to personnel or dam-
age to equipment, use only shear
lockwire (0.020 INCH copper) to safety
chop collar.
e. Install lockwire on grip (1) and grip control
collar (3). Use wire (item 220, App F).
f. Inspect (QA).
g. Install collective stick grip assembly (para
11.24).
END OF TASK
M04-3750-5