CPG COLLECTIVE STICK SUPPORT ASSEMBLY DISASSEMBLY/ASSEMBLY (AVIM) continued
NOTE
Maintain a gap of 0.002 INCH between
lever and arm.
e. Install lever (16) on arm (12).
(1) Position lever (16) on arm (12).
(2) Install
new
shear
rivet
(17)
dry
(TM 1-1500-204-23).
f. Install detent (13) on arm (11).
(1) Position detent (13) on arm (11).
(2) Install two screws (14) and washers (15).
NOTE
Detent will be secured and adjusted
when SPAD switch is installed.
g. Install arm (11) on arm (12).
GO TO NEXT PAGE
16
17
12
M04-4285-7
14
15
11
13
M04-4285-8
11
12