TM 1-1520-238-23
11-327
11.72.
CPG CYCLIC STICK REMOTE CONTROL LEVER REMOVAL/INSTALLATION
11.72.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
11.72.2. Initial Setup
Tools:
Aircraft mechanics tool kit (item 376, App H)
0 - 75 inch-pound 1/4-inch drive dial indicator torque
wrench (item 446, App H)
Materials/Parts:
Cotter pin (3)
Personnel Required:
67R
Attack Helicopter Repairer
67R3F
Attack Helicopter Repairer/Technical
Inspector
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
11.72.3. Removal
a. Enter CPG station (para 1.56). Observe all
safety precautions.
b. Remove lever (1) from upper fitting (2).
(1) Remove and discard cotter pin (3).
(2) Remove washer (4).
c. Remove lever (1) from link (5).
(1) Remove and discard cotter pin (6).
(2) Remove pin (7) and washer (8).
GO TO NEXT PAGE
CPG STATION
M04-1686-1
M04-1686-2
3
4
2
7
1
5
8
6