TM 1-1520-238-23
11-334
11.74.
CPG CYCLIC STICK WIRE ROPE RELEASE FITTING REMOVAL/INSTALLATION continued
11.74.6. Installation
a. Install fitting (1) on cable (5).
(1) Install fitting (1) on end of cable (5).
(2) Install new cotter pin (6).
b. Connect fitting (1) with cable (5) to lever (2).
(1) Insert fitting (1) through lever (2).
(2) Install washer (4) on fitting (1).
(3) Install new cotter pin (3).
c. Inspect (QA).
END OF TASK
5
1
6
4
2
3
M04-1688-4