11.74.
CPG CYCLIC STICK WIRE ROPE RELEASE FITTING REMOVAL/INSTALLATION continued
11.74.3. Removal
a. Enter CPG station (para 1.56). Observe all
safety precautions.
b. Remove fitting (1) from lever (2).
(1) Remove and discard cotter pin (3).
(2) Remove washer (4), fitting (1), and cable (5).
c. Remove fitting (1) from cable (5).
(1) Remove and discard cotter pin (6).
(2) Separate fitting (1) from cable (5).
11.74.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
11.74.5. Inspection
a. Check removed and attaching parts for
cracks. None allowed.
b. Check removed and attaching parts for dam-
age (para 11.5).
c. Check removed and attaching parts for corro-
sion (para 1.49).