TM 1-1520-238-23
11-805
11.182. MOTIONAL TRANSDUCER REMOVAL/INSTALLATION
11.182.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
11.182.2. Initial Setup
Tools:
Aircraft mechanics tool kit (item 376, App H)
13/16 x 3/8-inch drive open end box socket wrench
crowfoot attachment (item 76, App H)
30 - 150 inch-pound 1/4-inch drive click type torque
wrench (item 435, App H)
Materials/Parts:
Wire (item 224, App F)
Personnel Required:
67R
Attack Helicopter Repairer
67R3F
Attack Helicopter Repairer/Technical
Inspector
References:
TM 1-1520-238-T
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
2.2
Access doors T250L, T250R, T290L,
T290R, and L325 opened
11.182.3. Removal
a. Turn rotating swashplate (1) so that one inter-
rupter (2) is positioned approximately 45 de-
grees on each side of transducer (3).
b. Remove lockwire from transducer (3).
c. Detach connector P57 (4) from transducer
MT32 (3).
GO TO NEXT PAGE
M04-3349-1
VIEW ROTATED
180º
2
4
1
3
M04-3349-2