TM 1-1520-238-23
11-806
11.182. MOTIONAL TRANSDUCER REMOVAL/INSTALLATION continued
d. Remove transducer (3) from bracket (5).
(1) Hold lower locknut (6).
(2) Remove upper locknut (7).
11.182.4. Cleaning
a. Wipe transducer and mounting bracket with a
clean rag.
11.182.5. Inspection
a. Check removed and attaching parts for dam-
age (para 11.5).
b. Check removed and attaching parts for corro-
sion (para 1.49).
c. Check connector for cuts or loose wires
(TM 55-1500-323-24).
11.182.6. Installation
a. Thread lower locknut (6) on transducer (3)
approximately 3/8 INCH.
b. Install transducer (3) through bracket (5) with
electrical connection pointing down.
c. Install locknut (7) on transducer (3).
GO TO NEXT PAGE
M04-3349-3
5
7
6
3