TM 1-1520-238-23
11-973
11.227.
STABILATOR CONTROLLER INSTALLATION continued
11.227.3. Installation
a. Install controller (1).
(1) Install four bolts (2) and washers (3).
b. Attach ground wire (4).
(1) Aline lug (5) with controller (1).
(2) Install bolt (6) through washer (7), lug (5), and
controller (1).
(3) Install washer (7) and nut (8) on bolt (6).
c. Attach connectors to controller (1).
(1) Controller No. 1.
(a) Attach connector P985 (9) to receptacle
J1 (10).
(b) Attach connector P986 (11) to receptacle
J2 (12).
(c) Attach connector P987 (13) to receptacle
J3 (14).
(2) Controller No. 2.
(a) Attach connector P989 (15) to receptacle
J1 (16).
(b) Attach connector P990 (17) to receptacle
J2 (18).
(c) Attach connector P991 (19) to receptacle
J3 (20).
d. Inspect (QA).
e. Perform stabilator maintenance operational
check (TM 1-1520-238-T).
f. Secure access doors T290L, T290R, and L325
(para 2.2).
END OF TASK
M04-2231-3
2
1
4
5
8
7
6
2
3
3
CONTROLLER NO. 1
14
13
12
10
9
11
CONTROLLER NO. 2
20
19
18
16
15
17
M04-2231-4
CONTROLLER NO. 2
M04-2231-5
20
19
18
16
15
17