TM 1-1520-238-23
11-978
11.229.
STABILATOR CONTROLLER INTERCONNECT CIRCUIT CARD ASSEMBLY (CCA)
REMOVAL/INSTALLATION (AVIM) continued
11.229.5. Inspection
a. Check removed and attaching parts for dam-
age (para 11.190).
b. Check removed and attaching parts for corro-
sion (para 1.49).
11.229.6. Installation
a. Attach circuit card (2) to retaining plate (1).
Torque 4 screws (10) and 16 screws (8) 48 to 54
INCH-OUNCES.
(1) Apply a uniform coat of sealing compound
primer to threads of four screws (10). Use
sealing compound primer (item 146, App F).
(2) Apply a uniform coat of sealing compound
primer to threads of four screws (10). Use
sealing compound (item 169, App F).
(3) Allow to air dry 40 MINUTES.
(4) Position retaining plate (1) on circuit card (2).
(5) Install four screws (10) and washers (9).
(6) Install one screw (8) through washer (9) and
chain (11) in plate (1).
(7) Install 15 screws (8) and washers (9).
(8) Torque 4 screws (10) and 16 screws (8) 48 to
54 INCH-OUNCES. Use torque wrench.
(9) Install cover (6) on receptacle J4 (7).
GO TO NEXT PAGE
7
10
9
8
9
8
9
M04-3607-2
6
2
1
11