TM 1-1520-238-23
11-977
11.229.
STABILATOR CONTROLLER INTERCONNECT CIRCUIT CARD ASSEMBLY (CCA)
REMOVAL/INSTALLATION (AVIM)
11.229.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
11.229.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Light duty laboratory apron (item 27, App H)
#1 phillips screwdriver bit (item 35, App H)
Chemical protective gloves (item 154, App H)
Adjustable air filtering respirator (item 262, App H)
1 - 100 inch-ounce 1/4-inch hexagon drive click type
torque wrench (item 437, App H)
Materials/Parts:
Sealing compound primer (item 146, App F)
Sealing compound (item 169, App F)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
Equipment Conditions:
Ref
Condition
11.228
Stabilator controller CCA A1 thru A4 re-
moved
11.229.3. Removal
a. Remove electronic retaining plate (1) and in-
terconnect circuit card assembly (2) from sta-
bilator controller (3).
(1) Remove 10 screws (4) and washers (5).
b. Remove circuit card (2) from plate (1).
(1) Remove cover (6) from receptacle J4 (7).
(2) Remove 16 screws (8) and washers (9).
(3) Remove four screws (10) and washers (9).
(4) Separate circuit card (2) from plate (1).
11.229.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
GO TO NEXT PAGE
6
M04-3607-1
3
2
7
9
8
54
98
9
10
1