TM 1-1520-238-23
11-984
11.231.
STABILATOR POSITION TRANSDUCER REMOVAL/INSTALLATION continued
11.231.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. One person stationed at left wing tip for com-
munications. Use headset and cord assembly.
WARNING
Movement of horizontal stabilator can
cause injury to personal. Do not actu-
ate horizontal stabilator during main-
tenance. If injury occurs, seek medical
aid.
c. On pilot aft circuit breaker panel, close STAB
circuit breakers MAN DC.
d. On pilot aft circuit breaker panel, open STAB
circuit breakers AUTO DC and AUTO AC.
e. Apply external electrical power (para 1.70).
f. Hold stabilator switch (1) on pilot collective
stick (2) to NU (nose up) until trailing edge of
stabilator (3) is full up.
g. Remove external electrical power (para 1.70).
h. On pilot aft circuit breaker panel, open STAB
circuit breakers MAN DC and MAN AC.
GO TO NEXT PAGE
FRICTION
INCREASE
ND
NU
RESET
2
3
1
M04-2262-5