TM 1-1520-238-23
11-985
11.231.
STABILATOR POSITION TRANSDUCER REMOVAL/INSTALLATION continued
i. Loosen bolt (4) on sensor clamp (5).
j. Remove lower screw (6) and washer (7) from
transducer mounting bracket (8).
k. Remove clamp (9).
(1) Remove screw (10), washer (11), and spacer
(12).
l. Remove two clamps (13) and (14).
(1) Remove screw (15), washer (16), and spacer
(17).
m. Detach transducer connector P1076 (18) from
receptacle J1076 (19).
n. On pilot aft circuit breaker panel, close STAB
circuit breakers MAN DC and MAN AC.
o. Apply external electrical power (para 1.70).
p. On pilot collective stick (2), hold stabilator
switch (1) to ND (nose down) until trailing
edge of stabilator (3) is full down.
q. Remove external electrical power (para 1.70).
r. On pilot aft circuit breaker panel, open STAB
circuit breakers MAN DC and MAN AC.
GO TO NEXT PAGE
M04-2262-1
M04-2262-2
8
17
14
16
15
13
18
19
7
10
11
9
12
6
5
4
FRICTION
INCREASE
ND
NU
RESET
2
3
1
M04-2262-6