TM 1-1520-238-23
11-986
11.231.
STABILATOR POSITION TRANSDUCER REMOVAL/INSTALLATION continued
s. Remove upper screw (20) and washer (21)
from bracket (8).
t. Remove transducer (22) from bracket (8).
(1) Remove four screws (23).
11.231.4. Cleaning
a. Wipe transducer mounting bracket and instal-
lation area with a clean rag.
11.231.5. Inspection
a. Check removed and attaching parts for dam-
age (para 11.190).
b. Check removed and attaching parts for corro-
sion (para 1.49).
11.231.6. Installation
a. Install transducer (22) on bracket (8).
(1) Install four screws (23).
b. Install transducer (22) with bracket (8) on sta-
bilator (3).
(1) Ensure transducer shaft (24) goes through
hole in clamp (5).
c. Install transducer mounting bracket (8) to sta-
bilator (3).
(1) Install upper screw (20) and washer (21).
d. On pilot aft circuit breaker panel, close STAB
circuit breaker MAN DC and MAN AC.
e. Apply external electrical power (para 1.70).
GO TO NEXT PAGE
M04-2262-8
21
20
23
22
24
3
22
8
5