TM 1-1520-238-23
11-1197
11.283.
RIGGING PILOT AND CPG COLLECTIVE STICK STOP BOLTS continued
h. Check that collective servocylinder lower le-
ver (10) is alined with upper edge of boss (11)
on servocylinder (12).
(1) If lower lever (10) is not alined with upper
edge of boss (11) on servocylinder (12), rig
controls between pilot collective stick and col-
lective servocylinder (para 11.282).
(2) If lower lever (10) is alined with upper edge of
boss (11) on servocylinder (12), go to next
step.
i. Measure and record distance between valve
arm (13) and collective servocylinder stop
bolt (14).
(1) This is measurement A. Use caliper.
j. Remove -3 rig pin (8) from stick (4) and hous-
ing (7).
k. Remove pilot collective warning flag (9).
l. Back off pilot collective stick up limit stop bolt
(15) and down limit stop bolt (16).
(1) Remove lockwire.
(2) Loosen jam nuts (17) and (18).
(3) Turn bolts (15) and (16) into housing (7).
m. Back off CPG collective stick up-limit stop
bolt (19) and down limit stop bolt (20).
(1) Remove lockwire.
(2) Loosen jam nuts (21) and (22).
(3) Turn stop bolts (19) and (20) into housing
(23).
GO TO NEXT PAGE
M04-3014-2
12
11
10
14
13
A
7
17
16
18
7
4
3
8
15
9
M04-3014-4
M04-3014-13
23
21
19
20
22
23
1
2