TM 1-1520-238-23
11-1199
11.283.
RIGGING PILOT AND CPG COLLECTIVE STICK STOP BOLTS continued
r. Adjust CPG collective stick up limit stop bolt
(19) for a 0.020 INCH gap between head of bolt
(19) and stick (2).
(1) With pilot stick (4) held in the full up position,
place 0.020 INCH thickness gage (25)
against CPG stick (2).
(2) Rotate up limit stop bolt (19) counterclock-
wise, until it contacts thickness gage (25).
(3) Hold stop bolt (19). Tighten jam nut (21).
(4) Lockwire stop bolt (19) to jam nut (21) and
housing (23). Use wire (item 221, App F).
s. Rotate friction lock (3) on pilot collective stick
(4) to ZERO.
t. Measure and record distance between actua-
tor rod end (26) and end of actuator piston
housing (27).
(1) This is measurement C. Use caliper.
u. Observe collective servocylinder piston (24)
travel.
v. Fully extend piston (24) by slowly lowering
pilot collective stick (4).
(1) Slowly lower pilot collective stick (4) until pis-
ton (24) is fully extended.
(2) Stop moving stick (4). Rotate friction lock (3)
counterclockwise to hold stick (4) in position.
GO TO NEXT PAGE
M04-3014-5
21
19
25
2
23
M04-3014-6
3
4
M04-3014-3
26
27
C
24
M04-3014-14
24