TM 1-1520-238-23
11-1220
11.287.
RIGGING PILOT AND CPG LONGITUDINAL CYCLIC STICK STOP BOLTS continued
h. Back off pilot forward cyclic limit stop bolt
(11) and aft limit stop bolt (12).
(1) Remove lockwire.
(2) Loosen two jam nuts (13).
(3) Turn stop bolts (11) and (12) into base (4).
i. Back off CPG forward cyclic limit stop bolt
(11) and aft limit stop bolt (12).
(1) Remove lockwire.
(2) Loosen two jam nuts (13).
(3) Turn stop bolts (11) and (12) into base (4).
j. Observe longitudinal servocylinder piston
(14) travel.
k. Fully retract piston (14) by slowly pushing for-
ward on stick (1).
(1) Slowly push forward on stick (1) until piston
(14) is fully retracted.
(2) Hold stick (1) in this position.
l. Measure and record distance between valve
arm (9) and stop bolt (10) on servocylinder (7).
(1) This is measurement B. Use caliper.
(2) If difference between measurement A and
measurement B is more than 0.030 INCH pull
cyclic stick (1) slowly aft until difference be-
tween measurement A and measurement B
is less than 0.030 INCH.
(3) Hold stick (1) in this position.
GO TO NEXT PAGE
4
CPG OR PILOT
M04-3018-4
11
13
13
12
10
9
B
7
14
M04-3018-5
1