CANOPY SEVERANCE INITIATOR HANDLE REMOVAL/INSTALLATION - continued
c. Remove initiator handle (8) from maintenance
station.
(1) Remove two screws (9) from bracket (10).
(2) Remove clamp (11).
(3) Remove sealing compound from nut (12),
washer (13), and airframe (14) (para 1.47).
(4) Remove lockwire from nut (12).
(5) Remove nut (15) and washer (16) from initia-
tor (8). Use open end wrench.
(6) Remove and discard packing with retainer
(17).
(7) Remove initiator handle (8) from bracket (10)
and airframe (14).
(8) Remove washer (13) and nut (12) from initia-
tor handle (8). Use open end wrench.
12.78.4. Cleaning
a. Wipe removed and attaching parts with a
clean rag.
12.78.5. Inspection
a. In pilot and CPG stations, check grommet for
deterioration (para 12.76).
b. Check initiator handle for damage (para
12.76).