TM 1-1520-238-23
12-329/(12-330 blank)
12.78.
CANOPY SEVERANCE INITIATOR HANDLE REMOVAL/INSTALLATION - continued
b. Install initiator handle (8) in maintenance sta-
tion. Torque nut (15) to 125 INCH-POUNDS.
(1) Install nut (12) and washer (13) on initiator
handle (8). Use open end wrench.
(2) Install initiator handle (8) through airframe
(14).
(3) Install new packing with retainer (17) on initia-
tor handle (8).
(4) Install washer (16) and nut (15) on initiator
handle (8).
(5) Position initiator handle (8) so that interfer-
ence will not exist with access cover.
(6) Torque nut (15) to 125 INCH-POUNDS. Use
crowfoot and torque wrench.
(7) Lockwire nut (12) to bracket (10). Use wire
(item 223, App F).
(8) Position clamp (11) on initiator handle (8).
(9) Install two screws (9) on bracket (10).
c. Apply sealing compound around edges of nut
(12) and washer (13). Use sealing compound
(item 179, App F) and brush (item 34, App F).
d. Inspect (QA).
e. Install detonation cord to initiator handle
(para 12.77).
f. Install optical relay tube (if removed)
(TM 1-1270-476-20).
g. Install pilot and/or CPG FIRE CONTROL panel
(if removed) (TM 9-1230-476-20-1).
END OF TASK
15
16
17
8
12
13
9
11
14
10
M04-3353-9