TM 1-1520-238-23
16-92
Change 8
16.19.
PYLON CIRCUIT CARD AND JETTISON WIRE HARNESS REMOVAL/INSTALLATION - continued
16.19.6. Repair
WARNING
Soldering iron can cause severe
burns to personnel and start fires. Ob-
serve all safety precautions when us-
ing soldering iron. If injury occurs,
seek medical aid.
a. Repair harness (2) by replacing insulator (12)
and firing contact pin (13).
(1) Remove sealing compound from pin (13)
(TM 55-1500-323-24).
(2) Desolder wires (14) and (15) from pin (13).
Use soldering iron (TM 55-1500-323-24).
(3) Solder wires (14) and (15) to new pin (13).
Use solder (item 189, App F) and soldering
iron (TM 55-1500-323-24).
(4) Install new insulator (12) on pin (13).
NOTE
The pin needs to be held firmly against
the face of the insulator as the sealing
compound is applied and the sealing
compound must be allowed to cure.
(5) Apply sealing compound to pin (13). Use
sealing compound (item 155, App F).
(6) Allow sealing compound to cure.
NOTE
This repair is typical for resistors R1 or
R2 replacement.
b. Repair card (4) by replacing resistor (16).
(1) Identify and desolder wires (17) and (18) on
ends of resistor (16). Use soldering iron
(TM 55-1500-323-24).
(2) Remove two nuts (19) and washers (20) from
resistor (16).
GO TO NEXT PAGE
M04-2942-6
12
13
15
14
2
20
M04-2942-8
4
18
19
16
19
20
17