16.18.
PYLON WIRE HARNESS REPLACEMENT - continued
k. Install clamp (23) on bracket (26).
(1). Install clamp (23) on wire harness (19).
(2). Install screw (24) through washer (25), clamp
(23), and bracket (26).
l. Install clamp (18) on bracket (22).
(1). Install clamp (18) on wire harness (19).
(2). Install screw (20) through washer (21), clamp
(18), and bracket (22).
m. Install wire harness (11) on bracket (3).
(1). Pin identified wires (13) and (14) to receptacle
J256 (12) (TM 55-1500-323-24).
(2). Install two clamps (15) on harness (11).
(3). Install two screws (16) through washers (17) and
clamps (15) and into bracket (3).
n. Install tie strap (72) on harness (11). Use strap
(item 193, App F).
o. Attach connector P513 (8) to receptacle J513
(9) on bracket (3).
p. Attach connector P512 (5) to receptacle J512
(6) on bracket (3).
q. Attach connector P511 (1) to receptacle J511
(2) on bracket (3).
r. Pin six identified wires (58) on terminal blocks
(59) and (60) (TM 55-1500-323-24).
s. Inspect (QA).
t. Install pylon aerial bracket (para 16.14).
u. Install pylon actuator and top plate (para 16.9).
v. Install pylon controller and controller bracket
(para 16.15).
w. Install multiplex remote terminal unit type II
(TM 9-1230-476-20-1).
END OF TASK