TM 1-1520-238-23
Change 8
16-87
16.18.
PYLON WIRE HARNESS REPLACEMENT - continued
d. Install connector P505 (40) on plate (42).
(1) Install ring (48) on connector (40). Use
retaining ring pliers.
(2) Position ring (48) with lugs (63) facing aft.
(3) Aline keyway (64) on connector (40) with
notch (65) in left hole (66) of plate (42).
(4) Position connector (40) through hole (66) un-
til ring (48) is against bottom of plate (42).
(5) Install compressed spring (39) and washer
(44) on connector (40).
(6) Position ring (43) with lugs (67) facing for-
ward.
(7) Install ring (43) on connector (40). Use
retaining ring pliers.
(8) Remove lockwire from spring (39).
e. Install connector P508 (41) on plate (42).
(1) Install ring (48) on connector (41).
(2) Position ring (48) with lug (71) facing aft.
(3) Aline keyway (68) on connector (41) with
notch (69) in right hole (70) of plate (42).
(4) Position connector (41) through hole (70) un-
til ring (48) is against bottom of plate (42).
(5) Install compressed spring (39) and washer
(44) on connector (41).
(6) Position ring (43) with lug (72) facing forward.
(7) Install ring (72) on connector (41). Use
retaining ring pliers.
(8) Remove lockwire from spring (39).
GO TO NEXT PAGE
64
40
63
48
42
39
44
43
67
M04-1219-1 1A
66
65
44
43
72
39
48
71
68
41
42
M04-1219-12A
69
70