46
Change 5
42
DASE INTERACTIVE FD/LS CHECK (cont)
42
2. Perform FD/LS check as follows:
TASK
RESULT
a. On CPG AUX/ANTI
ICE panel (fig.247 ),
set ADSS switch to
ADSS.
b. On DEK (fig.249 ),
rotate DATA ENTRY
switch to FD/LS
(ADC). On CDU (fig.
249.2), select FAB
If there are no system
failures, the following
message (prompt) appears:
ANY KEY FOR FD/LS
MENUS
FDLS (ADD).
When a list of failures is
displayed, the list is scrolled
by pressing and releasing
the ENTER/ SPACE key on
the DEK (ADC) or SPC key
on the CDU (ADD). Scroll
until the following message
(prompt) appears: ANY KEY
FOR FD/LS MENUS
c. Obtain maintenance
menu by pressing
and releasing any
DEK key except
ENTER SPACE or
SHIFT (ADC); or
any key on the CDU,
except SPC (ADD).
If FD/LS menus do not
appear on HOD (fig.234),
refer to TM 9-1230-476-20-2
for troubleshooting the MUX
system.
NOTE
RHE RT BUS NOGO RH FAB (ACZ) and/or
RHE LT BUS NOGO RH FAB (ACZ) will
appear if both pilot and CPG SAFE/ARM
switches are off.
d. On DEK, press and
release ()/0 and
VWX/8 keys (ADC).
On CDU, press and
release 0 and 8 keys
If any MUX NOGO appears
on HOD, refer to
TM 9-1230-476-20-2 for
troubleshooting the MUX
system.
(ADD).
When MUX
COMMUNICATION GO
appears on the HOD, go to
next step.