TM 11520238T1
Change 5
451
47
MSL SYSTEM INTERACTIVE FD/LS
47
CHECK (cont)
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
MISSILE 1 NOGO LT
OUTBD appears on
HOD.
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
missile 1
(TM 9-1425-475-20).
MISSILE 2 NOGO LT
OUTBD appears on
HOD.
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
missile 2
(TM 9-1425-475-20).
MISSILE 3 NOGO LT
OUTBD appears on
HOD.
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
missile 3
(TM 9-1425-475-20).
MISSILE 4 NOGO LT
OUTBD appears on
HOD.
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
missile 4
(TM 9-1425-475-20).
MISSILE 1 NOGO LT
INBD appears on
HOD.
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
missile 5
(TM 9-1425-475-20).
MISSILE 2 NOGO LT
INBD appears on
HOD.
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
missile 6