TM 11520238T1
456
Change 5
48
MUX SYSTEM INTERACTIVE FD/LS
48
CHECK (cont)
TASK
RESULT
NOTE
RHE RT BUS NOGO RH FAB (ACZ) and/or
RHE LT BUS NOGO RH FAB (ACZ) will
appear if both pilot and CPG SAFE/ARM
switches are off.
d. On DEK, press and
release ()/0 and
VWX/8 keys (ADC).
On CDU, press and
When MUX
COMMUNICATION GO
appears on the HOD, go to
next step.
release 0 and 8 keys
(ADD).
If one or more FD/LS
NOGO displays listed below
appear on the HOD, perform
the following in sequence:
(1) Perform SYSTEMS
POWER DOWN
(para 32).
(2) Perform CORRECTIVE
ACTION indicated for first
NOGO displayed on
HOD.
(3) Perform SYSTEMS
POWERUP
(para 31).
(4) On DEK, rotate DATA
ENTRY switch to STBY
for 5 seconds, then back
to FD/LS (ADC).
(5) Repeat FD/LS check
beginning with step b. If
NOGO repeats after
CORRECTIVE ACTION,
refer to
TM 9-1230-476-20-2 for
troubleshooting the MUX
system.
NOTE
Record all NOGOs before rotating DATA
ENTRY switch to STBY (ADC).
e. On DEK, rotate
DATA ENTRY switch
to STBY (ADC).