TM 11520238T1
448
Change 5
47
MSL SYSTEM INTERACTIVE FD/LS
47
CHECK (cont)
TASK
RESULT
(b) Perform
CORRECTIVE
ACTION indicated for
first NOGO
displayed on HOD.
(c) Perform SYSTEMS
POWERUP
(para 31).
(d) Repeat FD/LS check
beginning with step 2.
If NOGO repeats
after CORRECTIVE
ACTION, refer to
TM 9-1427-475-20.
NOTE
Record all NOGOs before rotating DATA
ENTRY switch to STBY (ADC).
s. On DEK, rotate
DATA ENTRY switch
to STBY (ADC).
NOTE
If this FD/LS check is to be followed by the
HME SYSTEM OPERATIONAL CHECK
(TM 9-1427-475-20), omit step 4. This
eliminates the need for the 6 to 9 minute HARS
gyro warmup period.
4. Perform SYSTEMS POWER DOWN (para 32), if
power is no longer required.