TM 11520238T1
Change 5
449
47
MSL SYSTEM INTERACTIVE FD/LS
47
CHECK (cont)
NOTE
HELLFIRE Missile System performs builtin
test (BIT) in the following sequence if all
launchers and missiles are present as shown
on the following figure.
Remote HELLFIRE Electronics (RHE)
All missile launchers simultaneously
Group A missiles simultaneously
Group B missiles simultaneously
Group C missiles simultaneously
Group D missiles simultaneously
13
15
14
16
11
10
12
9
7
6
8
3
5
2
4
1
VIEW FROM REAR
SEQUENCE FOR MISSILE RANKING AND BIT
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
REMOTE HELLFIRE
ELECT NOGO RH
FAB
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
RHE (TM 9-1427-475-20).
MISSILE LAUNCHER
NOGO LT OUTBD
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace left
outboard launcher
(TM 9-1427-475-20).