TM 11520238T1
Change 5
453
47
MSL SYSTEM INTERACTIVE FD/LS
47
CHECK (cont)
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
MISSILE 1 NOGO RT
OUTBD appears on
HOD.
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
missile13
(TM 9-1425-475-20).
MISSILE 2 NOGO RT
OUTBD appears on
HOD.
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
missile14
(TM 9-1425-475-20).
MISSILE 3 NOGO RT
OUTBD appears on
HOD.
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
missile15
(TM 9-1425-475-20).
MISSILE 4 NOGO RT
OUTBD appears on
HOD.
Troubleshoot wiring to isolate
fault (TM 9-1427-475-20). If
troubleshooting does not
remove NOGO, replace
missile16
(TM 9-1425-475-20).
PYLON BORESIGHT
NOGO RAM
CHECKSUM
Refer to TM 9-1230-476-20-1
for boresight editing and
insert correctors from the
aircraft logbook. If FCC
battery is suspect, refer to
TM 9-1230-476-20-2 (ACY).
END OF TASK