415 UTIL INTERACTIVE FD/LS CHECK (cont)
415
TASK
RESULT
NOTE
Record all NOGOs before rotating DATA
ENTRY switch to STBY (ADC).
e. On DEK, rotate
DATA ENTRY switch
to STBY (ADC).
NOTE
If this FD/LS check is to be followed by a
MULTIPLEX SYSTEM OPERATIONAL
CHECK (TM 9-1230-476-20-2), omit step 3.
3. Perform SYSTEMS POWER DOWN (para 32) if
power no longer required.
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
BACKUP BUS
CONTROLLER
NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2). If
troubleshooting does not
remove NOGO, replace
Type IIIA MRTU
(TM 9-1230-476-20-1). If
replacement does not
remove NOGO,replace FCC
(TM 9-1230-476-20-1). If
NOGO still exist, refer to
TM 9-1230-476-20-2.
DATA ENTRY
KEYBOARD NOGO
CPG COMPARTMENT
(ADC)
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2). If
troubleshooting does not
remove NOGO, replace
DEK (TM 9-1230-476-20-1).
If NOGO still exist, refer to
TM 9-1230-476-20-2.
CPG FIRE CONTROL
PANEL NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 9-1230-476-20-2). If
troubleshooting does not
remove NOGO, replace
CPG FIRE CONTROL panel
(fig. 233)
(TM 9-1230-476-20-1) .If
NOGO still exist, refer to
TM 9-1230-476-20-2.
END OF TASK