TM 11520238T3
24
Change 4
210 SIGNAL NAME:
ADS LONG VEL
MEMORY LOCATION: 002140
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor HOD; zero velocity should be indicated on the ground.
SIGNAL FUNCTION:
Sends longitudinal velocity data to FCC and stabilator control units (SCUs).
REMARKS: From ADP through DASEC to FCC and SCUs.
PASS:
If CONDITION corresponds to proper velocity indication, go to paragraph 211.
FAIL: Location of fault: ADP, wiring from ADP to aft avionics module, aft avionics module, wiring to
DASEC, DASEC. Troubleshoot wiring to isolate fault (TM 91230476202).
211 SIGNAL NAME:
OAS SIDESLIP ANGLE
MEMORY LOCATION: 002137
MEMORY DATA BIT(S):
419 (ACY) 415 (ACZ)
(SCALAR)
CONDITION:
Monitor HOD; zero velocity should be indicated on the ground.
SIGNAL FUNCTION:
Sends ADS sideslip angle data to FCC.
REMARKS: From ADP through DASEC to FCC.
PASS:
If CONDITION corresponds to proper sideslip indication, refer to TM 91230476202.
FAIL: Location of fault: ADP, wiring from ADP to DASEC, DASEC. Troubleshoot wiring to isolate fault
(TM 91230476202).