TM 11520238T3
Change 4
33
33 SIGNAL NAME:
DASEC STATUS WORD OUTPUT CLEAR
MEMORY LOCATION: 002077
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of power up clear latch.
REMARKS: From DASEC to FCC.
PASS:
If first digit displayed on HOD is 6, go to paragraph 34.
FAIL: Location of fault: replace DASEC (TM 1152023823).
34 SIGNAL NAME:
DASEC STATUS WORD DISCRETE OUTPUT BIT (ACY) DO BIT (ACZ)
MEMORY LOCATION: 002077
MEMORY DATA BIT(S):
16
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of 5 VDC and 28 VDC discretes.
REMARKS: From DASEC to FCC.
PASS:
If second digit displayed on HOD is 1, 3, 5, or 7, go to paragraph 35.
FAIL: Location of fault: replace DASEC (TM 1152023823).
35 SIGNAL NAME:
DASEC STATUS WORD DC ANALOG OUTPUT BIT (ACY) DCO BIT (ACZ)
MEMORY LOCATION: 002077
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of DC analog circuits.
REMARKS: From DASEC to FCC.
PASS:
If second digit displayed on HOD is 3 or 7, go to paragraph 36.
FAIL: Location of fault: replace DASEC (TM 1152023823).
36 SIGNAL NAME:
DASEC STATUS WORD AD/DA BIT (ACY) ADA BIT (ACZ)
MEMORY LOCATION: 002077
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of analogtodigital and digitaltoanalog circuits.
REMARKS: From DASEC to FCC.
PASS:
If third digit displayed on HOD is 1, 3, 5, or 7, go to paragraph 37.
FAIL: Location of fault: replace DASEC (TM 1152023823).
37 SIGNAL NAME:
DASEC STATUS WORD FD/LS TEST
MEMORY LOCATION: 002077
MEMORY DATA BIT(S):
12
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates fault detection and location system (FD/LS) ground test is being run.
REMARKS: From DASEC to FCC.
PASS:
If third digit displayed on HOD is 1 or 5, go to paragraph 38.
FAIL: Location of fault: replace DASEC (TM 1152023823).