TM 11520238T3
34
Change 4
38 SIGNAL NAME:
DASEC STATUS WORD ASE BIT (ACY) DASE BIT STATUS (ACZ)
MEMORY LOCATION: 002077
MEMORY DATA BIT(S):
11
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates last FD/LS test ASE bit status.
REMARKS: From DASEC to FCC.
PASS:
If third digit displayed on HOD is 1, go to paragraph 39.
FAIL: Location of fault: replace DASEC (TM 1152023823).
39 SIGNAL NAME:
DASEC STATUS WORD SERIAL DIGITAL ERROR (ACY) S/D ERROR (ACZ)
MEMORY LOCATION: 002077
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of heading attitude reference system (HARS) ability to
acknowledge whether an error has been flagged.
REMARKS: From DASEC to FCC.
PASS:
If fourth digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 310.
FAIL: Location of fault: replace DASEC (TM 1152023823).
310 SIGNAL NAME:
DASEC STATUS WORD TERMINAL FLAG
MEMORY LOCATION: 002113
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of bits 16, 15, or 13.
REMARKS: From DASEC to FCC.
PASS:
If first digit displayed on HOD is 0, 2, 4, or 6, go to paragraph 311.
FAIL: Location of fault: go to paragraph 313.
311 SIGNAL NAME:
DASEC STATUS WORD BIT PROCESSOR (ACY) CPU BIT STATUS (ACZ)
MEMORY LOCATION: 002113
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates ability of word bit processor to work properly.
REMARKS: From DASEC to FCC.
PASS:
If first digit displayed on HOD is 2 or 6, go to paragraph 312.
FAIL: Location of fault: replace DASEC (TM 1152023823).
312 SIGNAL NAME:
DASEC STATUS WORD OUTPUT CLEAR
MEMORY LOCATION: 002113
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of power up latch.
REMARKS: From DASEC to FCC.
PASS:
If first digit displayed on HOD is 6, go to paragraph 313.
FAIL: Location of fault: replace DASEC (TM 1152023823).