TM 11520238T3
32
Change 5
FAILURE SYMPTOM INDEX (cont)
Symptom
Refer to paragraph
CPG DIR 2 DCPLR NOGO CPG COMPARTMENT . . . . . . . . . . . . . . . . . . . . . .
3125
CPG COLL 1 DCPLR NOGO CPG COMPARTMENT . . . . . . . . . . . . . . . . . . . .
3126
CPG COLL 2 DCPLR NOGO CPG COMPARTMENT . . . . . . . . . . . . . . . . . . . .
3127
CPG CYCLIC GRIP NOGO CPG COMPARTMENT . . . . . . . . . . . . . . . . . . . . . . 3128
CPG BUCS SEL NOGO CPG COMPARTMENT . . . . . . . . . . . . . . . . . . . . . . . . . 3129
TURN RATE INDICATOR NOGO PLT COMPARTMENT . . . . . . . . . . . . . . . . .
3130
Personnel Required:
(2)
References:
TM 1152023823
TM 11520238T7
Equipment Conditions:
Ref
Condition
TM 11520238T7
DIGITAL AUTOMATIC
STABILIZATION
EQUIPMENT (DASE)
MAINTENANCE
OPERATIONAL CHECK in
progress
NOTE
All multiplex read code responses are read from right to
left.
Multiplex read codes must be used in conjunction with
applicable Maintenance Operational Check (MOC) in
progress.
Multiplex read codes are observed on the HOD (ADC) or
CDU (ADD).
MULTIPLEX READ CODE INTERPRETATIONS
31 SIGNAL NAME:
DASEC STATUS WORD TERMINAL FLAG
MEMORY LOCATION: 002077
MEMORY DATA BIT(S):
19
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of bits 16, 15, or 13.
REMARKS: From digital automatic stabilization equipment computer (DASEC) to fire control
computer (FCC).
PASS:
If first digit on heads out display (HOD) is 0, 2, 4, or 6, go to paragraph 32.
FAIL: Location of fault: go to paragraph 34.
32 SIGNAL NAME:
DASEC STATUS WORD BIT PROCESSOR (ACY) CPU BIT STATUS (ACZ)
MEMORY LOCATION: 002077
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates ability of word bit processor to work properly.
REMARKS: From DASEC to FCC.
PASS:
If first digit displayed on HOD is 2 or 6, go to paragraph 33.
FAIL: Location of fault: replace DASEC (TM 1152023823).